Case study · Drone inspection · Industrial chimney

Drone thermal inspection of a 75 m operating chimney

Radiometric thermal imaging, RGB and thermal 3D models and a total-station cross-check located 59 defects on a reinforced-concrete stack, including hot flue gas escaping at four levels and a 0.535 m lean. The chimney stayed in service throughout, and nobody had to work at height to collect the data.

Surveyed
17 October 2026
Site visits
One
Flying time
Under 2 hours
RGB and thermal 3D models of a 75 m reinforced-concrete chimney built from a drone survey
3D models built from the drone survey, viewed from the north-east: visible (left) and thermal (right).

Key results

anomalies located and rated, 6 critical and 27 major
59
openings leaking hot flue gas, 44 above 140 °C
93
lean at 74 m towards the north-east (1 in 139)
0.535 m
estimated remaining life of the shell without major works
≈11 years

Also: 2,419 photographs and 61 minutes of visible and thermal video; measured height 79.3 m, 4.3 m more than the records show.

The challenge

The client needed the chimney’s true condition: the concrete shell, hotspots and gas leakage, height and verticality, the platforms, ladder, cap and fixings, and how long it can safely stay in service.

It could not be shut down. Close inspection of a stack this tall normally means rope access or scaffolding beside hot flue gas, and gives spot observations rather than a complete, measurable record.

The project

Client
Industrial client, India (name withheld)
Structure
Reinforced-concrete (RCC) chimney, 75 m nominal, 79.3 m measured, in operation
Scope
Visual and radiometric thermal inspection, RGB and thermal 3D models, verticality analysis, anomaly register, remaining-life estimate
Data capture
One site visit, under two hours of flying (October 2026)

The outcome

Overall condition: poor, serviceable in the short term only with urgent action. Instead of a list of observations, the client received a prioritised, time-bound action plan.

Without major works the shell has an estimated 11 years (8–15) of service life left; rehabilitation by 2028 would extend this to about 2050–2055.

Method

From 2,419 photographs to a measured record

  1. 1

    One survey, stack running

    2,419 photographs

    The drone flew vertical strips from 1 m to 86 m at 6–25 m stand-off: 1,198 visible and 1,221 radiometric thermal photographs, 61 minutes of video and a laser range on every frame. The hot gas made every leak visible.

  2. 2

    Every frame on the structure

    2,399 of 2,419 frames placed

    Each photograph was registered on the tapered, leaning shell from the same-day total-station survey, giving RGB and thermal 3D models and unwrapped maps at 5 mm and 15 mm per pixel.

  3. 3

    Systematic detection

    131 hotspots confirmed

    Each hotspot was seen in at least three views and at least 10 °C above its surroundings. Cracks were mapped on the orthomosaic, and every photograph and both videos were reviewed.

  4. 4

    Verticality from survey data

    15 survey levels

    Total-station measurements were turned into deviation angles and A3 CAD drawings, and checked independently against the drone’s laser-rangefinder data.

  5. 5

    A register to act on

    59 anomalies rated

    Each anomaly was located by height and bearing, rated from 1 (minor) to 4 (critical), illustrated and linked to an action and time frame.

Mapped shell

The whole chimney, unwrapped

Every point on the unwrapped maps has a height and a compass bearing. The 131 confirmed hotspots are circled; the leaking opening rows show as bright bands.

Anomalies by severity

Critical6 of 59
Major27 of 59
Moderate22 of 59
Minor4 of 59
Unwrapped thermal map of the whole chimney shell with hotspots circled
Thermal map, 25–65 °C
Unwrapped visible orthomosaic of the chimney shell with hotspots circled
Visible orthomosaic

Findings

59 anomalies, 6 of them critical

The shell is in poor condition, and the stack is serviceable in the short term only with urgent action.

  • Hot flue gas escaping through the shell

    93 openings in four rows, at about 38, 48, 58 and 68 m, were leaking gas, 44 of them above the thermal camera’s 140 °C range. The leakage indicates that the liner or its seals have failed, and cracking and rust staining were worst at exactly these rows.

  • A 0.535 m lean towards the north-east

    At 74 m the stack is 0.535 m off vertical (1 in 139, 0.41°). The axis is straight, so this is a rigid tilt of 3.6 to 7 times typical construction tolerance. Repeat surveys were recommended to establish whether it is still moving.

  • Taller than its records

    The measured height to the top of the steel cap is 79.3 m (±0.7 m), 4.3 m more than the 75 m in the records.

  • Critical defects on the steelwork

    A platform beam perforated by corrosion (a 150–200 mm hole through the web), a missing anchor on the top collar, a sampling-port flange held by one of its eight bolts, missing fasteners on the steel cap and defects in the lightning protection.

  • Falling hazards

    A loose 0.5 m patch of concrete under the top deck, flaking paint and plaster, and loose objects on a platform.

  • A concrete shell in poor condition

    An average zone rating of 3.2 out of 5, with cracking and rust bleeding concentrated at the leaking rows, between 60 and 71 m and near the base.

Thermal and visible photographs of the 38 m opening row, showing openings leaking hot gas above 140 °C
The ≈38 m opening row: thermal photograph (left) with the visible photograph taken at the same moment (right). Four of the six openings in view are above 140 °C.

Evidence

Defects found on the shell and steelwork

Every item in the register comes with annotated photographs like these.

  • Cracks with rust staining around openings in the concrete shell

    Cracks with rust staining

    Around the openings of the ≈38 m row: probable corrosion of the reinforcement.

  • Platform beam with a corrosion hole through its web

    Perforated platform beam

    A 150–200 mm corrosion hole through the web of a platform beam (video frame).

  • Sampling-port blind flange held by a single bolt

    Flange on one of eight bolts

    A sampling-port blind flange held by a single bolt (telephoto).

  • Loose delaminated concrete patch under the top deck of the chimney

    Loose concrete under the top deck

    A loose, delaminated 0.5 m patch: a falling hazard (video frame).

Verticality

A rigid lean of 1 in 139

Shell-centre offsets were measured at 15 levels with a total station. The best-fit line is straight, so the whole stack is tilted rather than bent: 0.535 m at 74 m, towards the north-east.

That is well outside the H/1000 and H/500 tolerance lines, so repeat surveys at 3 and 9 months were recommended to confirm whether it is still moving.

Charts of shell-centre deviation at the survey levels, showing a straight 1 in 139 lean to the north-east
Shell-centre offsets at the survey levels (left) and deviation against height (right).

Deliverables

What the client received

  • A formal condition report: executive summary, severity-rated anomaly register, annotated photographs, verticality analysis and remaining-life assessment
  • CAD drawings of the verticality survey (A3 PDF and DXF) and a 3D DXF in survey coordinates
  • RGB and thermal 3D models (GLB and OBJ), unwrapped orthomosaics and point clouds
  • Anomaly and hotspot registers as spreadsheets (CSV)
  • An interactive 3D anomaly viewer that runs in a web browser, even offline
3D anomaly viewer showing pins and outlined defect areas on the chimney model next to a finding sheet
The 3D anomaly viewer: defects pinned and outlined on the model, with the finding sheet and thermal photograph of the selected item.
Aligned thermal and visible photographs of a cracked area with hotspot temperatures marked
Opening an item shows its thermal and visible photographs side by side, aligned so each temperature can be read on the visible image too.

Action plan

A deadline for every finding

The register sorts the findings into time frames, so the client can plan safety measures, shutdown work and repairs straight from it.

  1. Now

    Make safe

    Close the affected platform, limit access to the top platform and barricade the drop zone below it.

  2. Within a month

    Remove hazards

    Remove loose concrete, replace missing anchors and fasteners, and clear loose objects.

  3. Next shutdown

    Inspect the liner

    Inspect the liner from inside and plan the repair of the leaking openings.

  4. At 3 and 9 months

    Re-survey the lean

    Repeat the verticality survey to confirm whether the lean is stable.

  5. Within two years

    Rehabilitate

    Targeted concrete testing, then concrete repair, protective coating and replacement of corroded platform steel.

The 3D models, maps and registers form a measured baseline, so the next survey can show exactly what has changed.

Why a drone survey

Inspect a live stack without climbing it

  • No shutdown: the stack stayed in operation, which is exactly when thermal imaging shows leaks
  • No work at height: nobody had to climb or hang beside hot flue gas to collect the data
  • Complete coverage: the whole shell is photographed and mapped, not sampled at a few access points
  • Every defect located: each finding has a height, a bearing and photographs, so crews go straight to it
  • Repeatable: the same flight plan and models give a baseline for tracking change over time

Services used

The services behind this project

Figures are from the inspection report for the survey of 17 October 2026. The client’s name and the chimney’s location are withheld.